Home > Productos > 隔离栅隔离栅

Isolation barrier is the connection unit between industry field instruments and control center, import
light, electric and magnetism isolation 
technology to realize the threeport isolation among power, 
input signal and 
output signal, efficiently solve the spot interference of industry automatic control 
system, and assure the stability and reliability of the system, with the function of signal isolation, 
conversion, allocation, 
alarming in automatic control systems.

ü Single/dual channels optional

ü Can realize the isolation & conversion between field signal and control center signal

ü Suited to various I/O system

ü Wiring terminal with hot plug and plan

ü DIN35 standard installation 


Application: widely used in petroleumchemical industry, metallurgy industry, electric power system

Including:Single Channel Low Housing Series,Analog Power Distribution,Resistance Tthermometry Series,Thermometry Input Series,Resistance Tthermometry/Thermometry Alarms Series,Surge Protection Thermometry Input Series

 Singel Channel Low Housing Series
Series NO. Remark Input Output Channel characteristic
T1100B Passive 4-20mA 4-20mA 1 input & 1output small size
Low-cost 
TxxyyB Voltage input
&Voltage output
0/1-5V,
0/2-10V
0/1-5V,
0/2-10V
1 input & 1output small size
Low-cost 
TxxyyB Voltage input
&Current output
0/1-5V,
0/2-10V
0/4-20mA 1 input & 1output small size
Low-cost 
TxxyyB Current input
&Current output
0/4-20mA 0/4-20mA 1 input & 1output small size
Low-cost 
TxxyyB Current input
&Voltage output
0/4-20mA 0/1-5V,
0/2-10V
1 input & 1output small size
Low-cost 
           
Analog Power Distribution
Series NO. Remark Input Output Channel characteristic
TA100 DC current input analog
isolation barrier with power distribution output
0/4-20mA 0/4-20mA,
0/1-5V,0/2-10V
1 input & 1 output with power distribution output
TA200 DC current input analog
isolation barrier with power distribution output
0/4-20mA 0/4-20mA,
0/1-5V,0/2-10V
2 input & 2 output with power distribution output
TA600 DC current input analog
isolation barrier with power distribution output
0/4-20mA 0/4-20mA,
0/1-5V,0/2-10V
1 input & 2 output with power distribution output
TA140 DC current input analog
isolation barrier with power distribution output
0/1-5V,0/2-10V 0/4-20mA,
0/1-5V,0/2-10V
1 input & 1 output with power distribution output
TA240 DC current input analog
isolation barrier with power distribution output
0/1-5V,0/2-10V 0/4-20mA,
0/1-5V,0/2-10V
2 input & 2 output with power distribution output
TA640 DC current input analog
isolation barrier with power distribution output
0/1-5V,0/2-10V 0/4-20mA,
0/1-5V,0/2-10V
1 input & 2 output with power distribution output
           
Resistance Tthermometry Series                                              Safety barrier programming software Download
Series NO. Remark Input Output Channel characteristic
TR100PI Programmable
resistance thermometry isolation barrier
Pt100,Cu50,Cu100 0/4-20mA,
0/1-5V,0/2-10V
1 input & 1 output  with RS485 interface
TR200PI Programmable
resistance thermometry isolation barrier
Pt100,Cu50,Cu100 0/4-20mA,
0/1-5V,0/2-10V
2 input & 2 output  with RS485 interface
TR600PI Programmable
resistance thermometry isolation barrier
Pt100,Cu50,Cu100 0/4-20mA,
0/1-5V,0/2-10V
1 input & 2 output  with RS485 interface
TR102PI Programmable resistance
thermometry isolation barrier
(output loop power supply)
Pt100,Cu50,Cu100 0/4-20mA,
0/1-5V,0/2-10V
1 input & 1 output  with RS485 interface
TR202PI Programmable resistance
thermometry isolation barrier
(output loop power supply)
Pt100,Cu50,Cu100 0/4-20mA,
0/1-5V,0/2-10V
2 input & 2 output  with RS485 interface
TR602PI Programmable resistance
thermometry isolation barrier
(output loop power supply)
Pt100,Cu50,Cu100 0/4-20mA,
0/1-5V,0/2-10V
1 input & 2 output  with RS485 interface
           
Thermometry Input Series                                                        Safety barrier programming software Download
Series NO. Remark Input Output Channel characteristic
TC100PI Programmable thermocouple
isolation barrier
R,S,K,J,T,B,E Thermometry;mV Signal 0/4-20mA,
0/1-5V,0/2-10V
1 input & 1 output with RS485 interface,
Cold junctioncompensation
TC600PI Programmable thermocouple
isolation barrier
R,S,K,J,T,B,E Thermometry;mV Signal 0/4-20mA,
0/1-5V,0/2-10V
1 input & 2 output with RS485 interface,Cold junctioncompensation
           
Resistance Tthermometry/Thermometry Alarms Series             Safety barrier programming software Download
Series NO. Remark Input Output Channel characteristic
TR/C103PI Resistance thermometry/ thermocouple ,input Programmable alarms Pt100,Pt1000,Cu50,Cu100,
R,S,K,J,T,B,E,mV Signal
0/4-20mA,
0/1-5V,0/2-10V
1 input & 1 output with RS485 interface
           
Surge Protection Thermometry Input Series                              Safety barrier programming software Download
Series NO. Remark Input Output Channel characteristic
TC100PI-SP Surge protection programmable thermocouple isolation barrier R,S,K,J,T,B,E Thermometry;mV Signal 0/4-20mA,
0/1-5V,0/2-10V
1input & 1output with RS485 interface,
Cold junctioncompensation
TC600PI-SP Surge protection programmable thermocouple isolation barrier R,S,K,J,T,B,E Thermometry;mV Signal 0/4-20mA,
0/1-5V,0/2-10V
1input & 2 output with RS485 interface,
Cold junctioncompensation