Isolation barrier is the connection unit between industry field instruments and control center, import
light, electric and magnetism isolation technology to realize the threeport isolation among power,
input signal and output signal, efficiently solve the spot interference of industry automatic control
system, and assure the stability and reliability of the system, with the function of signal isolation,
conversion, allocation, alarming in automatic control systems.
ü Single/dual channels optional
ü Can realize the isolation & conversion between field signal and control center signal
ü Suited to various I/O system
ü Wiring terminal with hot plug and plan
ü DIN35 standard installation
Application: widely used in petroleum, chemical industry, metallurgy industry, electric power system
Including:Single Channel Low Housing Series,Analog Power Distribution,Resistance Tthermometry Series,Thermometry Input Series,Resistance Tthermometry/Thermometry Alarms Series,Surge Protection Thermometry Input Series
| Singel Channel Low Housing Series |
| Series NO. |
Remark |
Input |
Output |
Channel |
characteristic |
| T1100B |
Passive |
4-20mA |
4-20mA |
1 input & 1output |
small size;
Low-cost |
| TxxyyB |
Voltage input
&Voltage output |
0/1-5V,
0/2-10V |
0/1-5V,
0/2-10V |
1 input & 1output |
small size;
Low-cost |
| TxxyyB |
Voltage input
&Current output |
0/1-5V,
0/2-10V |
0/4-20mA |
1 input & 1output |
small size;
Low-cost |
| TxxyyB |
Current input
&Current output |
0/4-20mA |
0/4-20mA |
1 input & 1output |
small size;
Low-cost |
| TxxyyB |
Current input
&Voltage output |
0/4-20mA |
0/1-5V,
0/2-10V |
1 input & 1output |
small size;
Low-cost |
| |
|
|
|
|
|
| Analog Power Distribution |
| Series NO. |
Remark |
Input |
Output |
Channel |
characteristic |
| TA100 |
DC current input analog
isolation barrier with power distribution output |
0/4-20mA |
0/4-20mA,
0/1-5V,0/2-10V |
1 input & 1 output |
with power distribution output |
| TA200 |
DC current input analog
isolation barrier with power distribution output |
0/4-20mA |
0/4-20mA,
0/1-5V,0/2-10V |
2 input & 2 output |
with power distribution output |
| TA600 |
DC current input analog
isolation barrier with power distribution output |
0/4-20mA |
0/4-20mA,
0/1-5V,0/2-10V |
1 input & 2 output |
with power distribution output |
| TA140 |
DC current input analog
isolation barrier with power distribution output |
0/1-5V,0/2-10V |
0/4-20mA,
0/1-5V,0/2-10V |
1 input & 1 output |
with power distribution output |
| TA240 |
DC current input analog
isolation barrier with power distribution output |
0/1-5V,0/2-10V |
0/4-20mA,
0/1-5V,0/2-10V |
2 input & 2 output |
with power distribution output |
| TA640 |
DC current input analog
isolation barrier with power distribution output |
0/1-5V,0/2-10V |
0/4-20mA,
0/1-5V,0/2-10V |
1 input & 2 output |
with power distribution output |
| |
|
|
|
|
|
| Resistance Tthermometry Series Safety barrier programming software Download |
| Series NO. |
Remark |
Input |
Output |
Channel |
characteristic |
| TR100PI |
Programmable
resistance thermometry isolation barrier |
Pt100,Cu50,Cu100 |
0/4-20mA,
0/1-5V,0/2-10V |
1 input & 1 output |
with RS485 interface |
| TR200PI |
Programmable
resistance thermometry isolation barrier |
Pt100,Cu50,Cu100 |
0/4-20mA,
0/1-5V,0/2-10V |
2 input & 2 output |
with RS485 interface |
| TR600PI |
Programmable
resistance thermometry isolation barrier |
Pt100,Cu50,Cu100 |
0/4-20mA,
0/1-5V,0/2-10V |
1 input & 2 output |
with RS485 interface |
| TR102PI |
Programmable resistance
thermometry isolation barrier
(output loop power supply) |
Pt100,Cu50,Cu100 |
0/4-20mA,
0/1-5V,0/2-10V |
1 input & 1 output |
with RS485 interface |
| TR202PI |
Programmable resistance
thermometry isolation barrier
(output loop power supply) |
Pt100,Cu50,Cu100 |
0/4-20mA,
0/1-5V,0/2-10V |
2 input & 2 output |
with RS485 interface |
| TR602PI |
Programmable resistance
thermometry isolation barrier
(output loop power supply) |
Pt100,Cu50,Cu100 |
0/4-20mA,
0/1-5V,0/2-10V |
1 input & 2 output |
with RS485 interface |
| |
|
|
|
|
|
| Thermometry Input Series Safety barrier programming software Download |
| Series NO. |
Remark |
Input |
Output |
Channel |
characteristic |
| TC100PI |
Programmable thermocouple
isolation barrier |
R,S,K,J,T,B,E Thermometry;mV Signal |
0/4-20mA,
0/1-5V,0/2-10V |
1 input & 1 output |
with RS485 interface,
Cold junctioncompensation |
| TC600PI |
Programmable thermocouple
isolation barrier |
R,S,K,J,T,B,E Thermometry;mV Signal |
0/4-20mA,
0/1-5V,0/2-10V |
1 input & 2 output |
with RS485 interface,Cold junctioncompensation |
| |
|
|
|
|
|
| Resistance Tthermometry/Thermometry Alarms Series Safety barrier programming software Download |
| Series NO. |
Remark |
Input |
Output |
Channel |
characteristic |
| TR/C103PI |
Resistance thermometry/ thermocouple ,input Programmable alarms |
Pt100,Pt1000,Cu50,Cu100,
R,S,K,J,T,B,E,mV Signal |
0/4-20mA,
0/1-5V,0/2-10V |
1 input & 1 output |
with RS485 interface |
| |
|
|
|
|
|
| Surge Protection Thermometry Input Series Safety barrier programming software Download |
| Series NO. |
Remark |
Input |
Output |
Channel |
characteristic |
| TC100PI-SP |
Surge protection programmable thermocouple isolation barrier |
R,S,K,J,T,B,E Thermometry;mV Signal |
0/4-20mA,
0/1-5V,0/2-10V |
1input & 1output |
with RS485 interface,
Cold junctioncompensation |
| TC600PI-SP |
Surge protection programmable thermocouple isolation barrier |
R,S,K,J,T,B,E Thermometry;mV Signal |
0/4-20mA,
0/1-5V,0/2-10V |
1input & 2 output |
with RS485 interface,
Cold junctioncompensation |
|