Designed according to GB3836.12000 & GB3836.42000 requirement, adopt unique patent
technology to realize the isolation between power, signal input and output, largely
improve the Antiinterference capability of the monitor and control circuit, very easy and
safe to use. Connect with all kinds of translators, electric/gas converter, electric/gas
valve localizer, approaching switch, electromagnetic valve, etc and compose intrinsically safe system.
Certification of explosion protection [Exia]IIC
Single/dual channels with very low cost
Signal transmission, conversion, allocation function optional
Suited to various I/O system
Imported PHOENIX covering
DIN35 standard installation
Application:widely used in petroleum, chemical industry, metallurgy industry, electric power system.
Inculding:Safety Switching Barrier, Analog signal isolation safety barrier, Programmable RTDs signal isolation safety barrier, Programmable RTDs signal isolation safety barrier(Loop Power Supply), Programmable thermocouples signal isolation safety barrier, Programmable thermocouples signal isolation safety barrier(With Surge protection) , Programmable thermocouples signal isolation safety barrier(Loop Power Supply), Communication signal isolation safety barrier
Safety barrier programming software Download
|
| Series |
Model Number |
Hazardous Area signals |
Signal transmission direction |
Safe Area signals |
Input Voltage |
Isolation Power Output |
Channel Numbers |
PDF |
|
Safety Switching Barrier
|
TS100-EX
|
Switch status of NUMAR sensor,mechanical joint etc |
→ |
Relay Output |
18-36VDC |
- |
1 input 1 output |
|
|
TS200-EX
|
2 input 2 output |
|
|
TS101-EX
|
→ |
Transistor Output |
18-36VDC |
- |
1 input 1 output |
|
|
TS201-EX
|
2 input 2 output |
|
|
TSF102-EX
|
Dry contact input |
← |
12VDC/44mA |
18-30VDC |
- |
1 input 1 output |
|
|
TSF202-EX
|
2 input 2 output |
|
|
Analog signal isolation safety barrier
|
TA100-EX
|
0/4-20mA |
→ |
0/4-20mA
0/1-5V
0/2-10V |
18-30VDC |
≤24VDC(open circuit)
≥18VDC(max current=20mA) |
1 input 1 output |
|
|
TA200-EX
|
2 input 2 output |
|
|
TA600-EX
|
1 input 2 output |
|
|
TA140-EX
|
0/1-5V
0/2-10V |
→ |
0/4-20mA
0/1-5V
0/2-10V |
18-30VDC |
≤24VDC(open circuit)
≥18VDC(max current=20mA) |
1 input 1 output |
|
|
TA240-EX
|
2 input 2 output |
|
|
TA640-EX
|
1 input 2 output |
|
|
TAF100-EX
|
0/4-20mA |
← |
0/4-20mA |
18-30VDC |
- |
1 input 1 output |
|
|
TAF200-EX
|
2 input 2 output |
|
|
TAF600-EX
|
1 input 2 output |
|
|
Programmable RTDs signal isolation safety barrier
|
TR100PI-EX
|
Pt100
Cu50
Cu100 |
→ |
0/4-20mA |
18-30VDC |
- |
1 input 1 output |
|
|
TR200PI-EX
|
2 input 2 output |
|
|
TR600PI-EX
|
1 input 2 output |
|
|
Programmable RTDs signal isolation safety barrier(Loop Power Supply)
|
TR102PI-EX
|
Pt100
Cu50
Cu100 |
→ |
0/4-20mA |
18-36VDC |
- |
1 input 1 output |
|
|
TR202PI-EX
|
2 input 2 output |
|
|
TR602PI-EX
|
1 input 2 output |
|
|
Programmable thermocouples signal isolation safety barrier
|
TC100PI-EX
|
R,S,K,J,T,B,E,mV-classs ignal |
→ |
0/4-20mA |
18-36VDC |
- |
1 input 1 output |
|
|
TC600PI-EX
|
1 input 2 output |
|
|
Programmable thermocouples signal isolation safety barrier(With Surge protection)
|
TC100PI-EX-SP
|
R,S,K,J,T,B,E,mV-classs ignal |
→ |
0/4-20mA |
18-36VDC |
- |
1 input 1 output |
|
|
TC600PI-EX-SP
|
1 input 2 output |
|
|
Programmable thermocouples signal isolation safety barrier(Loop Power Supply)
|
TC102PI-EX
|
R,S,K,J,T,B,E,mV-classs ignal |
→ |
0/4-20mA |
18-36VDC |
- |
1 input 1 output |
|
|
TC602PI-EX
|
1 input 2 output |
|
|
Communication signal isolation safety barrier
|
TD100-EX-485
|
RS485 Half-duple signal |
→ |
RS485 Half-duple signal |
18-32VDC |
Vo=5V/6V.Io≤100mA; Vo=8V/9V/12V.Io≤50mA |
1 input 1 output |
|
|
TD101-EX-485
|
RS232signal |
1 input 1 output |
|
|
TD102-EX-485
|
RS-485 Full-duplex digital signal |
RS485 Full-duplex signal |
5V、6V:I≤100mA
8V、9V:I≤50mA |
1 input 1 output |
|
|
TD103-EX-485
|
RS-232 digital signal |
1 input 1 output |
|
| |
|